Thermo Scientific Nicolet RaptIR FTIR Microscope

Specifications
  • High-performance visual (4X) and infrared (15X) imaging delivered by diffraction-limited objectives.
  • Multi-position automated nosepiece, autofocus, auto illumination, and a full-view computer-controlled aperture.
  • Visual spatial resolution at 1 micron, and infrared spatial resolution at better than 5 microns to obtain high-resolution images and absorbance spectra.
  • Supports reflectance, transmission, and ATR sampling modes & includes built-in ATR sensors to deliver user-adjustable pressure control.
  • Heavy-duty stage to accommodate samples up to 40 millimeters thick and 5 kilograms in weight.
  • Fast results with mapping of up to 10 spectra/second.
  • Automated data acquisition and analysis through OMNIC Paradigm software.
  • Option to install a grazing angle infrared objective for thin-layer analysis. 
Contact:  
Technical Specialist: cillian.odonovan@dcu.ie
Admin: research.facilities@dcu.ie
Price:  
Academic: €10/hr
Industry: On request

Applied Photophysics Chirascan Plus Circular Dichroism Spectroscopy


Specifications:
  • Wavelength Range: 170–1,150 nm
  • Wavelength Accuracy: ±0.2 nm (170–400 nm), ±0.5 nm (>400 nm)
  • Wavelength Precision: ±0.05 nm (170–400 nm), ±0.1 nm (>400 nm)
  • Resolution: 0.1 nm
  • Stray Light: <5 ppm @ 200 nm, <8 ppm @ 180 nm
  • Baseline Stability: ±0.02 mdeg/hr (@ 290 nm)
  • RMS Noise: 0.02–0.05 mdeg (depending on wavelength)
Featured Publications:

Gibney, A. et al. (2023a) ‘A click chemistry‐based artificial metallo‐nuclease’, Angewandte Chemie International Edition, 62(38). doi:10.1002/anie.202305759.

Holden, L. et al. (2023b) ‘Selective, disruptive luminescent ru(ii) polypyridyl probes of G-Quadruplex’, Inorganic Chemistry, 62(5), pp. 2213–2227. doi:10.1021/acs.inorgchem.2c03903.


Contact:  
Technical Specialist: stephen.fuller@dcu.ie
Admin: research.facilities@dcu.ie
Price:  
Academic: €9/hr
Industry: On request


Perkin Elmer LS55 Fluorescence Spectrometer

Specifications:
  • Pulsed xenon source
  • Excitation Range: 200–800 nm
  • Emission Range: 200–900 nm
  • Independent or synchronous scanning of monochromators to aid in method development and peak identification
  • 4 measurement modes; Fluorescence, Phosphorescence, Chemiluminescence & Bioluminescence
  • Excitation and emission scans
  • Constant wavelength synchronous and constant energy synchronous scans
  • 3D excitation/emission scans and 3D synchronous scans
  • Kinetic scans (single and multiple wavelength)
  • Simultaneous kinetics for multiple samples
Contact:  
Technical Specialist: stephen.fuller@dcu.ie
Admin: research.facilities@dcu.ie
Price:  
Academic: €5/hr
Industry: On request


Shimadzu UV-2600 and UV-1800 UV-VIS Scanning Spectrophotometers 


Specifications
  • Wavelength accuracy of ±0.3nm throughout the entire range
  • Wavelength repeatability of ±0.05nm (2600) and ±0.1nm (1800)
  • Resolution of ±0.1nm (2600) and  ±1nm (1800)
  • Photometric range between -5 to +5 Abs (2600) and -4 to +4 Abs (1800)
  • Photometric accuracy as low as ±0.002 Abs
  • Photometric repeatability as low as ±0.001 Abs
Contact:  
Technical Specialist: stephen.fuller@dcu.ie
Admin: research.facilities@dcu.ie
Price:  
Academic: €5/hr
Industry: On request


PerkinElmer Spectrum Two FTIR


Specifications:
  • Spectral range of 350 – 8,300 cm⁻¹
  • High-performance DLATGS detector
  • Better than 0.5 cm⁻¹ resolution
  • Diamond Universal ATR (robust, versatile sampling option)
Contact:  
Technical Specialist: leah.nolan@dcu.ie
Admin: research.facilities@dcu.ie
Price:  
Academic: €5/hr
Industry: On request


Shimadzu Prominence HPLC

Specifications:
  • Pump flow range: 0.001 – 10 mL/min, precision ≤0.1% RSD
  • Autosampler with injection volumes from 0.1 – 100 µL
  • Detector options: UV-Vis & PDA
  • Wavelength Range: 190 nm - 700 nm (+/-1 nm)
  • Modular, high-sensitivity system for analytical and semi-preparative use
  • Column oven: Columns < 150mm in length 25oC - 150oC, Columns < 310mm in length 25oC - 90oC
Contact:  
Technical Specialist: stephen.fuller@dcu.ie
Admin: research.facilities@dcu.ie
Price:  
Academic: €6/hr